Multichannel Analyzer Electronic Module only for Gamma Spectroscopy
Designed by RH Electronics in Israel
Buy with confidence.
Our Tindie Guarantee protects your purchase from fraud. Learn More
Nuclear Pioneer MCA Multichannel Analyzer Electronic Module only. package with BLE module The MCA can work as a robust Gamma Spectrometer and as a Scintillation Counter Survey Meter. It has high cou…
Read More…Nuclear Pioneer MCA Multichannel Analyzer Electronic Module only. package with BLE module
The MCA can work as a robust Gamma Spectrometer and as a Scintillation Counter Survey Meter. It has high count rate performance for spectrum mode and for scintillation search mode.
The board has regulated high voltage circuit with adjustable output of 600V-1000V postive polarity that allows to connect a NaI(Tl) probe with BNC cable. Probes with high impedance divider of ~50Meg-120Meg are supported. The pulse pre-amplifier set for an optimal gain, however you can re-adjust it if required.
The MCA can detect Gaussian shape peaks in real-time. It has small library of radionuclides for hobby Gamma Spectroscopy.
The counter calculate energy compensated doserate or can subtract previously saved background data file from the spectrum in real-time during spectrum acquisition.
The RH-MCA-4-Module SKU is for Nuclear Pioneer electronic module only. The package include fully soldered electronic board with BNC connector and encoder. To use the MCA you need to add NaI(Tl) scintillation probe, BNC cable, LiPo battery, CR2032 battery and MicroSD card. Calibration of hardware and software is required to set a correct gain for your NaI(Tl) probe.
Nuclear Pioneer MCA can work with small and big volume NaI(Tl) crystals probes. You may need to re-adjust high voltage with small screwdriver after connecting the probe to set the total gain of the analog circuit. Pulse pre-amplifier circuit is set for optimal pulse shape and gain, however in some circumstance you may need to re-adjust the pre-amplifier gain ratio (manual is included).
Channel-to-Energy scale polynomial calibration can be done with selecting a scheme from the menu and simple picking 3-points on spectrum. Automatic calibration of CPS standard deviation for scintillation mode can be triggered from the menu. Other software settings are changed through serial port commands in UART-USB terminal. The MCA has full speed 12MBit/sec USB port for calibration or spectrum data download.
Any further firmware updates can be done with friendly Arduino Teensy bootloader by connecting USB cable and selecting ready hex file to upload.
The board has additional 400V high voltage circuit for connecting 400V Geiger Counter. The board has space to install a tiny SBM-21 sensor. Any 400V GM tube is electrically compatible. The GM sensor CPS readings can be used in scintillation mode during prospecting in high radiation areas.
The MCA unit require to add CR2032 coin battery for date/hour keeping. The MCA unit require LiPo 3.7V rechargable battery for powering. Battery can be charged with USB cable 5V input. The MCA consumes 250mA-350mA current, depending on LCD backlight level settings.
MCA ver.4 specifications:
The performance of the gamma spectrometer is strictly depending on your NaI(Tl) scintillation probe specifications and hardware/software calibration of the unit. Please avoid shorting high voltage on BNC socket and do not use hot plug of the probe because HV arcing across the BNC jack can ruin sensitive electronics. Recommended BNC cable part number CT2942-100. Recommended BNC jack for probe is 31-221-RFX.
Menu description:
RETURN – return from menu to current working mode display RESTART – restart a new spectrum SAVE SPECTRUM – will safe CSV file to uSD card with name XXXXXXXX.CSV, For example, 19051207.CSV file from 19 May 12:07 local time VIEW SPECTRUM – load CSV file from uSD card LCD ZOOM X – change LCD spectrum zoom 512-4096 channels LCD SCALE Y – toggle between linear and linear+log scale BACKGROUND – set or turn on/off background subtract mode UNLOCK CALIBRATION – allows to unlock 3-points channel-to-energy calibration and to select calibration scheme SPECTRUM TIME – set time in seconds for spectrum acquisition BACKLIGHT – change LCD backlight level SIGMA icon (on/off) – activate CPS standard deviation calibration for scintillation mode MCA icon – toggle gamma spectrometer mode SCI icon – toggle scintillation counter mode GM Tube icon – toggle internal Geiger Counter circuit (active in SCI mode only)
Package Include:
1pcs of Nuclear Pioneer MCA electronic module with BLE
Item can be shipped with Fedex / DHL / EMS only
No country selected, please select your country to see shipping options.
No rates are available for shipping to .
Enter your email address if you'd like to be notified when Nuclear Pioneer MCA Multichannel Analyzer can be shipped to you:
Thanks! We'll let you know when the seller adds shipping rates for your country.
Shipping Rate | Tracked | Ships From | First Item | Additional Items |
---|---|---|---|---|
:
|
Buy with confidence.
Our Tindie Guarantee protects your purchase from fraud. Learn More
$25.00
Free Shipping!
$125.00
Free Shipping!
$175.00
Free Shipping!
$45.00
Free Shipping!
$150.00
Free Shipping!
$50.00
Free Shipping!
$35.00
Free Shipping!
$45.00
Free Shipping!
$65.00
Free Shipping!
$32.99
Free Shipping!
$25.00
Free Shipping!
$25.00
Free Shipping!
By clicking Register, you confirm that you accept our Terms & Conditions
We recognize our top users by making them a Tindarian. Tindarians have access to secret & unreleased features.
We look for the most active & best members of the Tindie community, and invite them to join. There isn't a selection process or form to fill out. The only way to become a Tindarian is by being a nice & active member of the Tindie community!